@article{Goulet2013261,
title = "Model falsification diagnosis and sensor placement for leak detection in pressurized pipe networks ",
journal = "Advanced Engineering Informatics ",
volume = "27",
number = "2",
pages = "261 - 269",
year = "2013",
note = "",
issn = "1474-0346",
doi = "http://dx.doi.org/10.1016/j.aei.2013.01.001",
url = "http://www.sciencedirect.com/science/article/pii/S1474034613000141",
author = "James-A. Goulet and Sylvain Coutu and Ian F.C. Smith",
keywords = "System identification",
keywords = "Leak detection",
keywords = "Sensor placement",
keywords = "Data interpretation",
keywords = "Water distribution ",
abstract = "Abstract Pressurized pipe networks used for fresh-water distribution can take advantage of recent advances in sensing technologies and data-interpretation to evaluate their performance. In this paper, a leak-detection and a sensor placement methodology are proposed based on leak-scenario falsification. The approach includes modeling and measurement uncertainties during the leak detection process. The performance of the methodology proposed is tested on a full-scale water distribution network using simulated data. Findings indicate that when monitoring the flow velocity for 14 pipes over the entire network (295 pipes) leaks are circumscribed within a few potential locations. The case-study shows that a good detectability is expected for leaks of 50 L/min or more. A study of measurement configurations shows that smaller leak levels could also be detected if additional pipes are instrumented. "
}
